Zenner WI-N Woltman Turbine Impeller 500mm Table E Flanged Water Meter
Configuration
Free Shipping
Australia Wide
30-Day Returns
Easy Returns
Tax Invoice
For Business Buyers
Expert Advice
1300 107 451
Product Overview
500mm Woltman turbine impeller water meter with Table E flanged connections, robust cast iron housing, encapsulated dry-dial register and 16 bar maximum operating pressure.
The Zenner WI-N 500mm Woltman Water Meter is designed for reliable measurement in demanding applications where water may contain significant levels of suspended particles or contamination. It is particularly suited to agricultural irrigation, bore water, sewage treatment plants, wastewater systems and raw-water applications.
Its Woltman measuring insert is positioned in the upper section of the pipe, where there are generally fewer suspended particles in the flowing water. This design allows the meter to operate reliably with polluted water and water containing suspended impurities. Where water is heavily contaminated, an external filter can be installed upstream of the meter.
The robust cast iron meter body incorporates a removable measuring insert for straightforward inspection and maintenance. Its completely encapsulated mechanical register helps protect the counter from dirt and harsh operating conditions. The meter is suitable for horizontal and vertical installation and is designed for cold water applications up to 50°C.
The 500mm WI-N is designed for high-volume water measurement in large agricultural irrigation, raw-water, wastewater and industrial systems. The DN500 configuration has a nominal flow rate of 2,500,000L/h and a maximum flow rate of 3,125,000L/h. The minimum flow rate is approximately 31,250L/h. The meter has a maximum operating pressure of 16 bar (1,600kPa).
A reed pulser can be retrofitted for connection to compatible monitoring equipment, data loggers, remote displays, irrigation controllers and control systems. For larger WI-N meters in the DN400–DN500 range, the standard pulse value is 10,000L per pulse, with alternative pulse values available on request.
Key features
- Woltman turbine impeller measurement technology
- Designed for polluted, raw and contaminated water
- 500mm nominal diameter
- Table E flanged connection
- Robust cast iron housing
- Removable measuring insert for easy maintenance
- Completely encapsulated mechanical dry-dial register
- Suitable for horizontal or vertical installation
- Nominal flow rate of 2,500,000L/h
- Maximum flow rate of 3,125,000L/h
- Minimum flow rate of approximately 31,250L/h
- Maximum operating pressure of 16 bar
- Maximum water temperature of 50°C
- Class A measuring accuracy
- Optional retrofittable reed pulser
- Standard 10,000L per pulse output for DN400–DN500 configurations
Applications
Frequently Asked Questions
What is the Zenner WI-N 500mm used for?
The Zenner WI-N 500mm is designed for high-volume measurement of polluted or untreated water in agricultural irrigation, bore-water systems, raw-water applications, sewage treatment plants and wastewater systems. It can also be used as a check or control meter for fresh-water applications.
What is the flow range?
The 500mm configuration has a minimum flow rate of approximately 31,250L/h, a nominal flow rate of 2,500,000L/h and a maximum flow rate of 3,125,000L/h.
Is the WI-N suitable for dirty or contaminated water?
Yes. The WI-N is designed for demanding water applications where suspended particles or impurities may be present. For heavily contaminated water, an external filter can be installed upstream of the meter.
What type of connection does the 500mm meter use?
The 500mm model uses a Table E flanged connection configuration. Confirm the exact supplied flange and bolt configuration against the meter before installation.
Can it be installed vertically?
Yes. The WI-N is suitable for both horizontal and vertical installation positions.
What is the maximum operating pressure?
The maximum operating pressure is 16 bar, equivalent to 1,600kPa.
Does the meter include a pulse output?
The meter is mechanical, but a reed pulser can be retrofitted for remote monitoring and data collection. For DN400–DN500 WI-N meters, the standard pulse value is 10,000L per pulse, with alternative pulse values available on request.
Downloads
Download product datasheets, manuals, and technical documents:
Product Reviews
See our product reviews here
Specifications
Maintenance Kits & Spare Parts
Compatible spare parts for this pump
Contact us for spare parts and maintenance kits.
Contact UsNeed a Trade Quote or Expert Advice?
Our team is here to help you find the right solution for your operation. Get personalised advice and competitive trade pricing.
Trade Pricing
Competitive rates for eligible businesses
Australia-Wide
Quick, reliable delivery
Expert Support
Real advice, real solutions
What Our Customers Say
"Incredible dosing and consistent results. Perfect for our irrigation needs."
Agriculture
"Simple to operate and built to last – exactly what we needed for fertigation."
Horticulture
"The team knows their stuff. Helped us choose the right dosing solution."
Water Treatment